{"id":22293,"date":"2026-09-03T08:53:33","date_gmt":"2026-09-03T06:53:33","guid":{"rendered":"https:\/\/pqc.es\/?p=22293"},"modified":"2026-09-03T08:53:41","modified_gmt":"2026-09-03T06:53:41","slug":"eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5","status":"publish","type":"post","link":"https:\/\/pqc.es\/en\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\/","title":{"rendered":"Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 5"},"content":{"rendered":"<p><strong><a href=\"https:\/\/www.datacentermarket.es\/sostenibilidad\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\/\">Enlace al art\u00edculo en la web de DCM<\/a><\/strong><\/p>\n<p class=\"wp-block-paragraph\">C<a href=\"https:\/\/www.datacentermarket.es\/sostenibilidad\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-4\/\" target=\"_blank\" rel=\"noreferrer noopener\" data-type=\"post\" data-id=\"39963\">err\u00e1bamos el anterior cap\u00edtulo\u00a0<\/a>mencionando que el\u00a0<strong>t\u00e9rmino CER (cooling efficiency ratio) ha adquirido un nivel de importancia\u00a0<\/strong>equiparable a PUE, WUE o ERF, y que a ello entrar\u00edamos con mayor detalle en el pr\u00f3ximo art\u00edculo.<\/p>\n<p class=\"wp-block-paragraph\">Sin embargo, considero necesario aplazar esas referencias para dedicar este art\u00edculo a uno de los\u00a0<strong>par\u00e1metros citados que ha cobrado un inter\u00e9s especial en los \u00faltimos tiempos<\/strong>\u00a0en su relaci\u00f3n con la entrada en los data centers de la inteligencia artificial.<\/p>\n<p class=\"wp-block-paragraph\"><strong>Se trata del PUE,<\/strong>\u00a0referencia que est\u00e1 siendo aludida desde muchos frentes con ocasi\u00f3n de la evoluci\u00f3n de las cargas IT, hacia la HPC y la IA y de la que se est\u00e1 diciendo de todo, una gran parte de lo cual\u00a0<strong>se hace sin verdadero sentido.<\/strong><\/p>\n<p class=\"wp-block-paragraph\">La pregunta que se est\u00e1n haciendo es\u00a0<strong>si realmente el concepto PUE puede seguir vivo<\/strong>\u00a0en tiempos donde existen fluctuaciones importantes de cargas IT, altas densidades de potencia no uniformemente distribuidas, elevados funcionamientos bajo carga parcial, crecientes proporciones de\u00a0<a href=\"https:\/\/www.datacentermarket.es\/dcm-xl\/refrigeracion-liquida-centro-de-datos-que-es-funcionamiento-componentes\/\" target=\"_blank\" rel=\"noreferrer noopener\" data-type=\"post\" data-id=\"32320\">\u00abliquid cooling\u201d<\/a>, etc., partiendo, todo ello, de la afirmaci\u00f3n de que PUE fue concebido para\u00a0<strong>cargas estables, densidades homog\u00e9neas, patrones predecibles de consumo y air cooling.<\/strong><\/p>\n<p class=\"wp-block-paragraph\">Pues no, PUE no fue concebido as\u00ed. Cuando \u201cThe Green Grid\u201d alumbr\u00f3 el concepto,\u00a0<strong>lo hizo de una manera mucho m\u00e1s simple<\/strong>. Se trataba de ver cu\u00e1nta energ\u00eda de m\u00e1s sobre la propia que utilizaban los equipos IT, se demandaba en la instalaci\u00f3n, es decir, cu\u00e1nta se \u201cescapaba\u201d para el cooling, las p\u00e9rdidas en\u00a0<a href=\"https:\/\/www.datacentermarket.es\/tendencias-ti\/los-sai-en-el-data-center-guia-practica\/\" target=\"_blank\" rel=\"noreferrer noopener\" data-type=\"post\" data-id=\"11802\">UPS<\/a>, la iluminaci\u00f3n y otros usos atribuibles al data center. Cuanto m\u00e1s cercano a 1, mayor aprovechamiento del\u00a0<strong>sistema electromec\u00e1nico.<\/strong><\/p>\n<h2 class=\"wp-block-heading\"><strong>PUE: un indicador frecuentemente malinterpretado<\/strong><\/h2>\n<p class=\"wp-block-paragraph\">Y ah\u00ed naci\u00f3 el primero de los errores. Eran tan sencillos el c\u00e1lculo y su aplicaci\u00f3n, que todo el mundo lo asumi\u00f3, pero lo hizo considerando\u00a0<strong>PUE como sin\u00f3nimo de eficiencia energ\u00e9tica del data center.\u00a0<\/strong>Y nada m\u00e1s lejos de la realidad.<\/p>\n<p class=\"wp-block-paragraph\">La eficiencia,\u00a0<a href=\"https:\/\/www.datacentermarket.es\/opinion\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-1\/\" target=\"_blank\" rel=\"noreferrer noopener\">como ha quedado indicado en anteriores cap\u00edtulos de esta serie<\/a>, se encuentra,\u00a0<strong>mayoritariamente, en el aprovechamiento de la parte IT<\/strong>\u00a0y, no necesariamente, un nivel de PUE m\u00e1s bajo significa un data center m\u00e1s eficiente, por lo tanto,\u00a0<strong>PUE no es directamente eficiencia.<\/strong><\/p>\n<p class=\"wp-block-paragraph\">Precisamente por eso,\u00a0<strong>nunca he sido un gran partidario de PUE<\/strong>, pero ahora que hay quien se pregunta si PUE est\u00e1 midiendo algo realmente representativo tengo que erigirme en un firme defensor, diciendo que \u00a1claro que s\u00ed!<\/p>\n<p class=\"wp-block-paragraph\">PUE, adem\u00e1s, tiene una naturaleza de media anual por lo que,\u00a0<strong>a igualdad de prestaciones y consumos IT,<\/strong>\u00a0quien consiga un nivel m\u00e1s bajo, mejor su rendimiento electromec\u00e1nico y, por extensi\u00f3n, su eficiencia general. \u00bfDe todos y cada uno de los componentes del sistema? Pues claro que no, sino del conjunto.<\/p>\n<h2 class=\"wp-block-heading\"><strong>La falacia del PUE pico<\/strong><\/h2>\n<p class=\"wp-block-paragraph\">Existe un empe\u00f1o actual por medir PUE de forma instant\u00e1nea, por reinventar ese concepto de \u201cPUE Pico\u201d o por sacarlo de contexto. Veamos:<\/p>\n<ul class=\"wp-block-list\">\n<li>Si entendemos PUE pico como el\u00a0<strong>m\u00e1ximo valor de ese par\u00e1metro alcanzado durante el a\u00f1o<\/strong>, su significado es apenas trascendente, de igual manera que la punta de arranque de un motor poco contribuye al consumo global del ciclo de trabajo o que un cortocircuito apenas altera la lectura de un transformador para la medida del consumo de energ\u00eda. Incluso si esas crestas fuesen muy repetitivas, la eficiencia en su gesti\u00f3n derivar\u00eda en una mejora de PUE.<\/li>\n<li>En un principio,<strong>\u00a0se establecieron cuatro formas de medir PUE<\/strong>, de menor a mayor precisi\u00f3n, siendo la primera de ellas (PUE<sub>0<\/sub>) una especie de PUE pico, ya que lo que se mide (a diferencia de PUE<sub>1<\/sub>\u00a0a PUE<sub>3<\/sub>\u00a0que miden energ\u00eda) es la m\u00e1xima potencia demandada por el conjunto del centro (kilovatios) y se divide por la m\u00e1xima potencia registrada a la salida de los UPSs de la parte de IT, situaciones ambas que, por otra parte, no tienen por qu\u00e9 coincidir exactamente en el tiempo.<\/li>\n<li><strong>PUE no es un factor de c\u00e1lculo<\/strong>, por lo que la consideraci\u00f3n del valor PUE pico no puede sustituir un balance b\u00e1sico de potencias que debe plantearse para la peor de las situaciones y donde, para el caso de los data centers tiene, adem\u00e1s, un factor de simultaneidad de 1.<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\">Se est\u00e1n esgrimiendo, tambi\u00e9n, afirmaciones en el sentido de que\u00a0<strong>presentar buenas cifras de PUE no implica que el data center en cuesti\u00f3n no presente operaciones ineficientes ante picos de carga\u00a0<\/strong>ni que los sistemas de enfriamiento est\u00e9n operando en su rango \u00f3ptimo. Pues claro que no, ni lo pretende. Incluso, he le\u00eddo en varios sitios relacionar esta situaci\u00f3n con arranques m\u00e1s frecuentes de los grupos de emergencia.<\/p>\n<p class=\"wp-block-paragraph\">Me da la impresi\u00f3n de que, como dice la expresi\u00f3n popular, aqu\u00ed alguien est\u00e1 confundiendo \u201cel culo con las t\u00e9mporas\u201d.<\/p>\n<p class=\"wp-block-paragraph\">El objetivo\u00a0<strong>nunca puede ser mejorar PUE a costa de debilitar la infraestructura,<\/strong>\u00a0sino hacer ambas l\u00edneas compatibles. Seg\u00fan dec\u00eda mi admirado Ken Brill, a quien hago referencia habitualmente, el primer objetivo de quienes estamos en esto de los data centers, es la\u00a0<strong>disponibilidad\u00a0<\/strong>y el segundo, la disponibilidad, y el tercero, tambi\u00e9n, y as\u00ed sucesivamente hasta encontrarnos, m\u00e1s abajo, con otros conceptos, entre los cuales podemos encontrar la eficiencia y la sostenibilidad.<\/p>\n<p class=\"wp-block-paragraph\">Si entran con frecuencia los grupos electr\u00f3genos\u00a0<strong>no veo yo conexi\u00f3n alguna con PUE.\u00a0<\/strong>Es m\u00e1s, existe un factor de conversi\u00f3n que transforma la cantidad de combustible utilizado, en energ\u00eda que a\u00f1adir al c\u00f3mputo global que va en el numerador de la f\u00f3rmula de c\u00e1lculo de PUE. Asimismo,\u00a0<strong>declarar unos logros de PUE sin decir \u201cni p\u00edo\u201d acerca del consumo de agua<\/strong>, tambi\u00e9n es hacerse trampas al solitario y \u201ca ver si cuela\u201d. PUE s\u00f3lo es v\u00e1lido si va de la mano de WUE.<\/p>\n<h2 class=\"wp-block-heading\"><strong>El verdadero alcance de PUE en la era de la IA<\/strong><\/h2>\n<p class=\"wp-block-paragraph\">Que un buen valor anual de PUE no refleje costes marginales de racks de alta potencia o ciertos funcionamientos a carga parcial o impactos de r\u00e1pidas fluctuaciones de carga sobre el sistema de alimentaci\u00f3n,\u00a0<strong>no dice nada.<\/strong>\u00a0Es como pretender que tras una inspecci\u00f3n cardiol\u00f3gica muy positiva uno quiera inferir que se encuentra libre de cualquier inflamaci\u00f3n de la pr\u00f3stata.\u00a0<strong>Cada cosa en su terreno.<\/strong><\/p>\n<p class=\"wp-block-paragraph\">PUE, con todos sus defectos que no son pocos, sirve para lo que sirve y estuvo bien parido.\u00a0<strong>El tiempo le ha puesto en un lugar interesante.<\/strong><\/p>\n<p class=\"wp-block-paragraph\">Las cargas actuales IT son muy diferentes de las que hemos conocido previamente y, pong\u00e1monos como nos pongamos,\u00a0<strong>el sentido de PUE sigue siendo plenamente vigente.\u00a0<\/strong>Preguntarse hasta d\u00f3nde es \u00fatil siempre est\u00e1 bien y la respuesta es que \u00fatil, lo que se dice \u00fatil<strong>, s\u00ed que sigue siendo, pero para lo que es, y s\u00f3lo para eso.<\/strong><\/p>\n<p class=\"wp-block-paragraph\">No ser\u00e9 yo quien se oponga a la multiplicaci\u00f3n de puntos de medida. El dec\u00e1logo de Google ten\u00eda como primer postulado<strong>\u00a0\u201cmedir, medir y medir\u201d y eso lo suscribo al pie de la letra<\/strong>\u00a0(s\u00f3lo se pueden tomar buenas decisiones si disponemos de datos), pero es tiempo ya de que todos entendamos cu\u00e1l es alcance verdadero de PUE, y contribuyamos a que la buena gente del sector, tanto con este asunto como con otros, como dir\u00eda un buen amigo m\u00edo, no se haga \u201cla l\u00eda un picho\u201d.<\/p>\n<p>&nbsp;<\/p>\n<p><em><strong>Art\u00edculos y\/o lecturas recomendadas:<\/strong><\/em><\/p>\n<p><a href=\"https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-1\/\"><u><strong>Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 1<\/strong><\/u><\/a><\/p>\n<p><a href=\"https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-2\/\"><u><strong>Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 2<\/strong><\/u><\/a><\/p>\n<p><a href=\"https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-3\/\"><u><strong>Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 3<\/strong><\/u><\/a><\/p>\n<p><a href=\"https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-4\/\"><u><strong>Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 4<\/strong><\/u><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Enlace al art\u00edculo en la web de DCM Cerr\u00e1bamos el anterior cap\u00edtulo\u00a0mencionando que el\u00a0t\u00e9rmino CER (cooling efficiency ratio) ha adquirido un nivel de importancia\u00a0equiparable a PUE, WUE o ERF, y que a ello entrar\u00edamos con mayor detalle en el pr\u00f3ximo art\u00edculo. Sin embargo, considero necesario aplazar esas referencias para dedicar este art\u00edculo a uno de [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-22293","post","type-post","status-publish","format-standard","hentry","category-sin-categorizar"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 5 | PQC<\/title>\n<meta name=\"description\" content=\"Enlace al art\u00edculo en la web de DCM Cerr\u00e1bamos el anterior cap\u00edtulo\u00a0mencionando que el\u00a0t\u00e9rmino CER (cooling efficiency ratio) ha adquirido un nivel de\" \/>\n<meta name=\"robots\" content=\"noindex, follow\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 5 | PQC\" \/>\n<meta property=\"og:description\" content=\"Enlace al art\u00edculo en la web de DCM Cerr\u00e1bamos el anterior cap\u00edtulo\u00a0mencionando que el\u00a0t\u00e9rmino CER (cooling efficiency ratio) ha adquirido un nivel de\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\/\" \/>\n<meta property=\"og:site_name\" content=\"PQC\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-03T06:53:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-03T06:53:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pqc.es\/wp-content\/uploads\/2026\/03\/IMAGEN_DEL_SITIO.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"625\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/pqc.es\\\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pqc.es\\\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/pqc.es\\\/#\\\/schema\\\/person\\\/66647e1005e9975e2dd2f7a1e9fa3ad6\"},\"headline\":\"Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 5\",\"datePublished\":\"2026-09-03T06:53:33+00:00\",\"dateModified\":\"2026-09-03T06:53:41+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/pqc.es\\\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\\\/\"},\"wordCount\":1333,\"publisher\":{\"@id\":\"https:\\\/\\\/pqc.es\\\/#organization\"},\"articleSection\":[\"Sin categorizar\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pqc.es\\\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\\\/\",\"url\":\"https:\\\/\\\/pqc.es\\\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\\\/\",\"name\":\"Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 5 | PQC\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pqc.es\\\/#website\"},\"datePublished\":\"2026-09-03T06:53:33+00:00\",\"dateModified\":\"2026-09-03T06:53:41+00:00\",\"description\":\"Enlace al art\u00edculo en la web de DCM Cerr\u00e1bamos el anterior cap\u00edtulo\u00a0mencionando que el\u00a0t\u00e9rmino CER (cooling efficiency ratio) ha adquirido un nivel de\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pqc.es\\\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pqc.es\\\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pqc.es\\\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/pqc.es\\\/en\\\/home\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pqc.es\\\/#website\",\"url\":\"https:\\\/\\\/pqc.es\\\/\",\"name\":\"PQC\",\"description\":\"Consultor\u00eda, dise\u00f1o y operaci\u00f3n de Data Centers\",\"publisher\":{\"@id\":\"https:\\\/\\\/pqc.es\\\/#organization\"},\"alternateName\":\"PQC Data Centers\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pqc.es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/pqc.es\\\/#organization\",\"name\":\"PQC Data Centers\",\"alternateName\":\"PQC\",\"url\":\"https:\\\/\\\/pqc.es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/pqc.es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/pqc.es\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/LOGO-PQC.svg\",\"contentUrl\":\"https:\\\/\\\/pqc.es\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/LOGO-PQC.svg\",\"width\":168,\"height\":40,\"caption\":\"PQC Data Centers\"},\"image\":{\"@id\":\"https:\\\/\\\/pqc.es\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/pqc\\\/posts\\\/?feedView=all\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/pqc.es\\\/#\\\/schema\\\/person\\\/66647e1005e9975e2dd2f7a1e9fa3ad6\",\"name\":\"admin\",\"sameAs\":[\"https:\\\/\\\/pqc.es\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 5 | PQC","description":"Enlace al art\u00edculo en la web de DCM Cerr\u00e1bamos el anterior cap\u00edtulo\u00a0mencionando que el\u00a0t\u00e9rmino CER (cooling efficiency ratio) ha adquirido un nivel de","robots":{"index":"noindex","follow":"follow"},"og_locale":"en_US","og_type":"article","og_title":"Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 5 | PQC","og_description":"Enlace al art\u00edculo en la web de DCM Cerr\u00e1bamos el anterior cap\u00edtulo\u00a0mencionando que el\u00a0t\u00e9rmino CER (cooling efficiency ratio) ha adquirido un nivel de","og_url":"https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\/","og_site_name":"PQC","article_published_time":"2026-09-03T06:53:33+00:00","article_modified_time":"2026-09-03T06:53:41+00:00","og_image":[{"width":1200,"height":625,"url":"https:\/\/pqc.es\/wp-content\/uploads\/2026\/03\/IMAGEN_DEL_SITIO.png","type":"image\/png"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\/#article","isPartOf":{"@id":"https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\/"},"author":{"name":"admin","@id":"https:\/\/pqc.es\/#\/schema\/person\/66647e1005e9975e2dd2f7a1e9fa3ad6"},"headline":"Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 5","datePublished":"2026-09-03T06:53:33+00:00","dateModified":"2026-09-03T06:53:41+00:00","mainEntityOfPage":{"@id":"https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\/"},"wordCount":1333,"publisher":{"@id":"https:\/\/pqc.es\/#organization"},"articleSection":["Sin categorizar"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\/","url":"https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\/","name":"Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 5 | PQC","isPartOf":{"@id":"https:\/\/pqc.es\/#website"},"datePublished":"2026-09-03T06:53:33+00:00","dateModified":"2026-09-03T06:53:41+00:00","description":"Enlace al art\u00edculo en la web de DCM Cerr\u00e1bamos el anterior cap\u00edtulo\u00a0mencionando que el\u00a0t\u00e9rmino CER (cooling efficiency ratio) ha adquirido un nivel de","breadcrumb":{"@id":"https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/pqc.es\/eficiencia-y-sostenibilidad-en-los-data-centers-capitulo-5\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/pqc.es\/en\/home\/"},{"@type":"ListItem","position":2,"name":"Eficiencia y sostenibilidad en los data centers. Cap\u00edtulo 5"}]},{"@type":"WebSite","@id":"https:\/\/pqc.es\/#website","url":"https:\/\/pqc.es\/","name":"PQC","description":"Consultor\u00eda, dise\u00f1o y operaci\u00f3n de Data Centers","publisher":{"@id":"https:\/\/pqc.es\/#organization"},"alternateName":"PQC Data Centers","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pqc.es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/pqc.es\/#organization","name":"PQC Data Centers","alternateName":"PQC","url":"https:\/\/pqc.es\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/pqc.es\/#\/schema\/logo\/image\/","url":"https:\/\/pqc.es\/wp-content\/uploads\/2026\/02\/LOGO-PQC.svg","contentUrl":"https:\/\/pqc.es\/wp-content\/uploads\/2026\/02\/LOGO-PQC.svg","width":168,"height":40,"caption":"PQC Data Centers"},"image":{"@id":"https:\/\/pqc.es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/pqc\/posts\/?feedView=all"]},{"@type":"Person","@id":"https:\/\/pqc.es\/#\/schema\/person\/66647e1005e9975e2dd2f7a1e9fa3ad6","name":"admin","sameAs":["https:\/\/pqc.es"]}]}},"_links":{"self":[{"href":"https:\/\/pqc.es\/en\/wp-json\/wp\/v2\/posts\/22293","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pqc.es\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pqc.es\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pqc.es\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pqc.es\/en\/wp-json\/wp\/v2\/comments?post=22293"}],"version-history":[{"count":2,"href":"https:\/\/pqc.es\/en\/wp-json\/wp\/v2\/posts\/22293\/revisions"}],"predecessor-version":[{"id":22300,"href":"https:\/\/pqc.es\/en\/wp-json\/wp\/v2\/posts\/22293\/revisions\/22300"}],"wp:attachment":[{"href":"https:\/\/pqc.es\/en\/wp-json\/wp\/v2\/media?parent=22293"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pqc.es\/en\/wp-json\/wp\/v2\/categories?post=22293"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pqc.es\/en\/wp-json\/wp\/v2\/tags?post=22293"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}